Harsh mix challenge
SUPERDOFFER 04-16-2011
comment profile send pm notify

Next Monday a challenge between a putz and a schwing 1200 m³ bridge deck whit a harsh mix. Last poor of 300 m³ a rookie on a 42m putz had trouble pumping it. His problem was he had never learnt to listen to his machine and did all on EOC and EBC.


mrpumpy 04-16-2011
reply profile send pm notify

i am realy curious about the outcome. so let us know will you?

SUPERDOFFER 04-16-2011
reply profile send pm notify

N9 / N248 Stolpen near Schagen

http://maps.google.nl/maps?q=N9%20stolpen&rls=com.microsoft:nl:IE-SearchBox&oe=UTF-8&rlz=1I7SUNA&redir_esc=&um=1&ie=UTF-8&sa=N&hl=nl&tab=wl


SUPERDOFFER 04-17-2011
reply profile send pm notify

the concrete is a C53/65 XF4. they upgraded him from a f4 to a f5 for the pumpability I heard today from the placing crew foreman  

SUPERDOFFER 04-18-2011
reply profile send pm notify

http://video.concretepumping.com/videos/983/the-man-in-bleu


SUPERDOFFER 04-19-2011
reply profile send pm notify


SUPERDOFFER 04-19-2011
reply profile send pm notify

The schwing won because of the bigger barrels of that unit. The problem with the mix was the pressure build up with the change of stroke. The schwing made less strokes on the same volume. The max output on the pumps was about 60/70 m³ an hour at an oil pressure of 200. We used 600 liter of fuel for 1150m³. rookie used 300 liter on 300m³


SUPERDOFFER 04-19-2011
reply profile send pm notify


pumper chuck 05-01-2011
reply profile send pm notify

nice tip hose.

SUPERDOFFER 05-03-2011
reply profile send pm notify

To change tip hose you need to have one whit you


SUPERDOFFER 05-03-2011
reply profile send pm notify

It's not alone the safety The boys hate to push around the extra kilo's all day. win/win